Hitachi Construction Machinery — Proportional Solenoid Valve

COMPONENT OPERATION / Drive Unit PROPORTIONAL SOLENOID VALVE Proportional splenoid valve is used as a pilot valve for the clutch oil pressure, and transfers oil to the modulation spool by receiving the electric signal from the controller, and by raising or lowering the oil pressure. Operation At Neutral: Spool (1) is pushed right by the spring (2), and outlet port S is connected with tank port T. At Excitement: Solenoid valve (3) pushes the spool (1) left with a force in proportion to the electric current flowing at the solenoid (3). Pilot pressure oil flows to output port S from port P, and the pressure at output port S rises.

This pressure at output port S works on the shoulder part ‘a’ of the spool (1). Shoulder part ‘a’ has different sectional areas, and generates a force to push the spool (1). When the pressure at output port S rises, and the force pushing the spool (1) right becomes larger than the force due to the solenoid (3) to push the spool (1) left, the spool (1) is returned to the right, the passage between output port S and port P is closed, and the pressure at output port S stops rising. T107-02-07-005 1 - Spool 2 - Spring 3 - Solenoid T3-9-38 S 1 2 3 T P a a