SYSTEM / Control System Automatic Warming Up Control Purpose: Automatic warming up of the engine in response to the hydraulic oil temperature Operation: Engine Actual Speed 1. At start of the engine, if the hydraulic oil temperature is 0°C (32°F) or below, the MC transmits signal to the ECM for setting the engine minimum speed at 1000 min -1 . Maximum Speed Automatic Warming Up Speed 2. ECM increases the minimum engine speed to 1000 min-1. Speed Increase 3. When the engine coolant temperature or hydraulic oil temperature is 40°C (104°F) or above, or when 10 minutes have passed, the MC stops signals, and the ECM decreases the engine minimum speed to the idling value.
Minimum Speed Minimum Speed Maximum Speed Target Engine Speed NOTE: At start of the engine, if the hydraulic oil temperature is 1°C (34°F) or above, automatic warming up control is not made. NOTE: In case the hydraulic oil temperature sensor becomes abnormal, automatic warming up control is not made. NOTE: When the parking brake switch is turned OFF, automatic warming up control is released. NOTE: In case automatic warming up control is released by Dr. ZX, retrieve the automatic warming up control effective by Dr. ZX the moment releasing becomes unnecessary. (Retrieving is impossible by just turning the key switch OFF.) T2-1-10