SYSTEM / Control System Reverse Traveling Alarm Control (Refer to the SYSTEM/Electric System) Purpose: Sounding alarm buzzer when the for- ward/reverse lever or the forward/reverse switch is selected Operation: 1. When reverse of the forward/reverse lever or the forward/reverse switch is selected, the MC earths the terminal from the reverse light relay. 2. Reverse light relay is excited, and electric current flows to the reverse light and the reverse buzzer. Right Reverse Light Reverse Buzzer MC ECM F N Monitor Unit R Left Reverse Light Reverse Light Relay Forward/Reverse Lever or Forward/Reverse Switch T4GC-02-01-024 From Terminal #108 of Fuse Box A T2-1-48