hyundai — 3. PILOT CIRCUIT

GROUP 3 PILOT CIRCUIT Remote control valve (LH lever) Remote control valve (RH lever) RCV pedal Safety lock solenoid valve Swing parking brake MCV Travel speed solenoid valve Line filter Main pump Relief valve 35kgf/cm 2 Pilot pump Suction strainer 210S3CI03 The pilot circuit consists of suction circuit, delivery circuit and return circuit. The pilot pump is provided with relief valve, receives the oil from the hydraulic tank through the suction filter. The discharged oil from the pilot pump flows to the remote control valve through line filter, and safety lock solenoid valve and flows to the travel speed solenoid valve, swing parking brake, main control valve and main pump. 3-6