Hyundai Construction Equipment — 2. ELECTRICAL CIRCUIT

1. POWER CIRCUIT The negative terminal of battery is grounded to the machine chassis. When the start switch is in the OFF position, the current flows from the positive battery terminal as shown below. 侍 GND :

Ground 4-5 4-5 1)OPERATING FLOW Battery Battery relay [CR-1] Fusible link [CN-60] Master switch [CS-74A] Fuse box [No.1] Master switch [CS-74B] I/conn [CN-8 (12)] Start switch [CS-2 (1)] Power relay [CR-35 (30)] Fuse box [No.2] I/conn [CN-10 (6)] Room lamp [CL-1 (2)] Door switch [CS-1] Radio & USB Player [CN-27 (8)] GPS connector [CN-125 (1)] Fuse box [No.3] I/conn [CN-11 (4)] AC&Heater controller (3,4) Relay [Hi/M2 (2)] Fuse box [No.5] I/conn [CN - 5 (4)] I/conn [CN -17 (5)] Wiper motor Controller [CN-141 (7)] Wiper motor [CN-21 (4)] RMS [CN-125A (1)] Fuse box [No.6] MCU [CN-50(7)] 侍 I/conn :

Intermediate connector 2) CHECK POINT Engine Start switch Check point Voltage 刮 - GND (battery 1 EA) 10~12.5V 刯 - GND (battery 2 EA) 20~25V STOP OFF 到 - GND (battery 2 EA) 20~25V 刱 - GND (reset button) 20~25V 1) OPERATING FLOW Battery Battery relay [CR-1] Fusible link [CN-60] Master switch [CS-74A] Fuse box [No.1] Master switch [CS-74B] I/conn [CN-8 (12)] Start switch [CS-2 (1)] Power relay [CR-35 (30)] Fuse box [No.2] I/conn [CN-10 (6)] Room lamp [CL-1 (2)] Door switch [CS-1] Radio & USB Player [CN-27 (8)] GPS connector [CN-125 (1)] Fuse box [No.3] I/conn [CN-11 (4)] AC&Heater controller (3,4) Relay [Hi/M2 (2)] Fuse box [No.5] I/conn [CN - 5 (4)] I/conn [CN -17 (5)] Wiper motor Controller [CN-141 (7)] Wiper motor [CN-21 (4)] RMS [CN-125A (1)] Fuse box [No.6] MCU [CN-50(7)] Engine Start switch Ch eck point Voltage STOP OFF 刮 - GND (battery 1 EA) 刯 - GND (battery 2 EA) 到 - GND (battery 2 EA) 刱 - GND (reset button) 10~12.5V 20~25V 20~25V 20~25V 侍 I/conn :

Intermediate connector