Hyundai Construction Equipment — 2. MODE SELECTION SYSTEM

2. WORK MODE SELECTION SYSTEM 3 work modes can be selected for the optional work speed of the machine operation.

PS PS PS Work pressure Travel pressure Attachment pilot pressure MCV Option Arm 1 Bucket Arm 2 Boom 2 Arm regen Swing Boom 1 Travel speed solenoid valve Travel(RH) Travel(LH) Swing priority Engine Engine speed sensor Coolant temp sensor Main pump Pilot pump Fuel injection pump Accel actuator Hyd temp sensor P M Engine speed sensor signal EPPR valve Potentiometer signal Motor drive signal Hyd temperature signal Drive signal Coolant temperature signal MCU Pressure switch signal Accel dial signal n/mi CN-19A CN-19B CN-19 Accel dial Serial communication(-) Serial communication(+) Drive signal Normal Emergency Battery Prolix resistor n/mi Cluster 210S5MS03 1) HEAVY DUTY WORK MODE 2) BREAKER OPERATION MODE It sets the pump flow to the optimal operation of breaker by MCU.

5-4