Hyundai Construction Equipment — 10. EPPR VALVE

3. EPPR VALVE CHECK PROCEDURE Spec : 100~700 mA 1) CHECK ELECTRIC CURRENT VALUE AT EPPR VALVE Adapter(P/no.:21Q6-50410) 刮 Disconnect connector CN-75 from EPPR valve. Multimeter CN-75 刯 Insert the adapter to CN-75 and install multimeter as figure. EPPR valve 到 Start engine. 刱 Set S-mode and cancel auto decel mode. 刲 Position the multimodal dial at 10. Main pump 刳 If engine rpm display show approx 1900 佳 100 rpm check electric current at bucket circuit relief position. 210S5MS21 刴 Check electric current at bucket circuit relief position. 2) CHECK PRESSURE AT EPPR VALVE 刮 Remove plug and connect pressure gauge as figure. 余 Gauge capacity : 0 to 50 kgf/cm 2 (0 to 725 psi ) 刯 Start engine.

到 Set S-mode and cancel auto decel mode. 刱 Position the multimodal dial at 10. 刲 If engine rpm display show approx 1900 佳 100 rpm check pressure at relief position of bucket circuit by operating bucket control lever. 刳 If pressure is not correct, adjust it. 刴 After adjust, test the machine. 5-21 Spec : 2~25 kgf/cm2 (30~350 psi) Pressure adjusting screw locknut Pilot pressure CN-75 supply line EPPR valve Main pump 210S5MS22