Hyundai Construction Equipment — 11. MONITORING SYSTEM

5-33 Group Display Name Description Group 2 CHECK Er : 03 Current error It shows that current error of 03(Short circuit in pump EPPR valve system) is diagnosed by self diagnosis system in the MCU. If more than 2 errors, when pressing or switch, other error codes show. Range : 00~58 TIME Er : 03 Recorded error It shows recorded error code of 03 which is diagnosed before. If more than 2 error codes, when pressing or switch, other error codes show. Range : 00~58 TIME Er : 00 Recorded error deletion It shows all recorded error codes are removed in the MCU memory. Group 3 PP : on or oFF Pump prolix switch PP : on Shows that pump prolix switch is turned on (At emergency position). PP :

oFF Shows that pump prolix switch is turned off(At normal position). dP : on or oFF Auto decel pressure switch dP : on Shows that auto decel pressure switch is pressed on (No operation of control lever). dP : oFF Shows that auto decel pressure switch is released off (Operation of control lever). Pb : on or oFF Power boost switch Pb : on Shows that power boost switch is pressed on (Activated). Pb : oFF Shows that power boost switch is released off (Canceled). oP : on or oFF Travel oil pressure switch oP : on Shows that travel oil pressure switch is pressed on (No operation of travel control lever). oP :

oFF Shows that travel oil pressure switch is released off (Operation of travel control lever). od : on or oFF One touch decel switch od : on Shows that one touch decel switch is pressed. od : oFF Shows that one touch decel switch is released. br : on or oFF Travel alarm switch br : on Shows that travel alarm function is selected. br : oFF Shows that travel alarm function is canceled.