Hyundai Construction Equipment — 3. ELECTRICAL SYSTEM

10. WHEN SAFETY SOLENOID DOES NOT OPERATE 余 Before disconnecting the connector, always turn the starting switch OFF. 余 Before carrying out below procedure, check all the related connectors are properly inserted and short of fuse No.26. 余 After checking, insert the disconnected connectors again immediately unless otherwise specified. MCU SAFETY LEVER SW 19 No.26 CN-50 210S6ES59 6-33 6-33 YES H YES Check operation m of solenoid D NO Safety lever : ON-OFF YES Check voltage YES between CS-4 Check voltage (C) and chassis between CN-68 D Check voltage Starting switch : ON NO (1) - CN-68 (2) YES between CN-4 Voltage : 20~30V w Starting switch : ON (8) and chassis Disconnect CN-4 p Voltage :

20~30V b Safety state Starting switch : ON C Voltage : 20~30V Disconnect CN-4 Check voltage D between CN-68 NO w NO (2) with chassis p Safety lever : OFF b Starting switch : ON C Voltage : 20~30V D NO f YES D Check voltage ( 刔 between CS-20 and chassis D NO Starting switch : ON ( Voltage : 20~30V Cause Remedy ydraulic alfunction efective solenoid 刔 isconnect in iring harness or oor contact etween N-4 (8)-CS-4 (C) isconnect in iring harness or oor contact etween N-4 (8)-CN-68 (1) isconnection in use efective switch CS-20) efective switch CS-4) Check hydraulic system Replace Repair or replace (After clean) Repair or replace (After clean) Replace Repair or replace Repair or replace