OPERATION STARTING ENGINE WITH BOOSTER CABLES When starting the engine with a booster cable, do as follows: CONNECTING AND DISCONNECTING BOOSTER CABLES When connecting the cables, never contact the positive (+) and negative (-) terminals. When starting the engine with a booster cable, always wear safety glasses. Be careful not to let the normal machine and problem machine contact each other. This prevents sparks from generating near the battery which could ignite the hydrogen gas given off by the battery. If hydrogen gas explodes, it could cause serious injury. Make sure that there is no mistake in the booster cable connections.
The final connection is to the upper structure frame, but sparks will be generated when this is done, so connect to a place as far as possible from the battery. (However, avoid connecting the cable to the work equipment, as conduction is poor.) Use care when removing the cables from a machine that has been started. To avoid hydrogen explosion, do not allow the cable ends to contact each other or the machine. Remark The starting system for this machine uses 24 Volts. For the normal machine, use a 24V battery. The size of the booster cable and clip should be suitable for the battery size. The battery of the normal machine must be the same capacity as that of the engine to be started.
Check the cables and clips for damage or corrosion. Make sure that the cables and clips are firmly connected. Check to be sure the safety lock levers are in the LOCK position. Check to be sure each lever is in the NEUTRAL position. PC400LC-7E0 2-139