Komatsu — PROCEDURE FOR BLEEDING AIR

OPERATION GENERAL TROUBLESHOOTING AFTER RUNNING OUT OF FUEL When starting the engine again after running out of fuel, fill with fuel, then bleed the air from the fuel system before starting the engine. PROCEDURE FOR BLEEDING AIR Remark This engine consists of higher precision parts than on the conventional fuel injection pump and nozzle, so if dirt gets in, it will cause problems. If there is any dirt stuck to the fuel line, use fuel to wash it off completely. Be careful when opening the air bleed plug at the fuel filter head. The system is still under pressure and fuel may spurt out. 1. Loosen bleed air plug (A) at the fuel main filter head (1). 2.

Loosen wing nut (4) holding lever (3) of the priming pump (2). 3. Push in lever (3) repeatedly. Check to be sure bubbles come out with the fuel from air bleed plug (A). 4. Tighten air bleed plug (A). Tightening torque: 11.8 Nm (8.7 ft/lbs) 5. Tighten wing nut (4) securely 6. Turn the ignition switch to the START position (C) and start the engine. 7. When doing this, do not crank the starter motor more than 20 seconds, wait at least 2 minutes, then try again. If the engine does not start, repeat the operation again. PC400LC-7E0 2-141