MAINTENANCE CHECK LEVEL OF BATTERY ELECTROLYTE Perform this inspection before operating the machine. Do not use the battery if the battery electrolyte level is below the LOWER LEVEL line. This will accelerate deterioration of the inside of the battery and reduce the service life of the battery. In addition, it may also cause an explosion. The battery generates flammable gas and there is danger of explosion. Do not bring fire or sparks near the battery. Battery electrolyte is dangerous. If it gets in your eyes or on your skin, wash it off with large amounts of water and consult a doctor.
Remark When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing. Inspect the battery electrolyte level at least once a month and follow the basic safety procedures given below. Open cover (1) at the front right side of the machine. The battery is inside. WHEN CHECKING ELECTROLYTE LEVEL FROM SIDE OF BATTERY 1. If it is possible to check the electrolyte level from the side of the battery, check as follows. Use a wet cloth to clean the area around the electrolyte level lines and check to be sure the electrolyte level is between the UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines.
If the battery is wiped with a dry cloth, static electricity may cause a fire or explosion. 2. If the electrolyte level is below the midway point between the UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines, remove cap (2) and add distilled water to the U.L. line. 3. After adding distilled water, tighten cap (2) securely. PC400LC-7E0 3-47