MAINTENANCE EVERY 5000 HOURS MAINTENANCE Maintenance for every 250, 500, and 1000 hours service should be performed at this time. CHANGE OIL IN HYDRAULIC TANK The parts and oil are hot after the engine is stopped and may cause serious burns. Wait for the temperature to cool before changing the oil in the hydraulic tank. When the oil filler cap is removed, oil may spurt out so turn the cap slowly to release the internal pressure, then remove it carefully. Remark If the machine is equipped with a hydraulic breaker, the hydraulic oil will deteriorate much faster than during normal bucket operations. Refill, capacity: 248 liters (65.52 US gal) Prepare a flex handle (for the socket wrench). 1.
Swing the upper structure so that hydraulic tank drain plug (P) and drain plug (A) at the bottom of the pump suction tube are in the middle between the left and right tracks. 2. Retract the arm and bucket cylinders, then lower the boom and put the teeth in contact with the ground. 3. Set the lock lever to the LOCK position and stop the engine. 4. Remove the cap of oil filler port (F) at the top of the hydraulic tank. 5. Remove the undercover(1) and (2). 6. Set the oil container under the drain plug under the machine. Using the flex handle, remove drain plug (P), (A) and drain the oil. Check the O-ring installed to plug (P), (A), and if it is damaged, replace the O-ring.
After draining the oil, tighten drain plug (P), (A). Torque drain plug (P) and (A): 58.8 to 78.5 Nm (43.3 to 57.9 lbft) When removing drain plug (P), (A), be careful not to get oil on yourself. First, remove drain plug (P) at the bottom of the tank, then remove drain plug (A) at the suction tube. If they are removed in this order, almost the same amount of oil can be drained. 7. Add the replacement amount of oil through oil filler (F). Check to be sure the oil level is between the H and L lines on the sight gauge (G). 8. Install the undercover (1) and (2). 9. Bleed air from the hydraulic circuit. PC400LC-7E0 3-75