BODY (UPPERSTRUCTURE) / Pilot Valve Assembly of 2-Way Lever Type Pilot Valve for Additional Circuit Thoroughly read and understand Cautions on Disassemble and Assemble on W1-1-1 before starting any assembling work. Clean all parts by using cleaning fluid and place the parts by port. 1. Install bushings (4) (2 used) to cover (11). IMPORTANT: Install shim (17) with the same thickness as it was assembled. 2. Install washers (16) (2 used), shims (17) (2 used), springs (18) (2 used) and spring guides (19) (2 used) to spools (15) (2 used) in this order. IMPORTANT: Install the spool (15) assembly into the same hole as it was disassembled. 3.
Install springs (14) (2 used) and the spool (15) assemblies (2 used) to casing (21). 4. Install O-rings (1) (2 used) and packings (3) (2 used) to bushings (2) (2 used). 8. Apply LOCTITE #241 onto set screw (8). Install set screw (8) to cam (9). Secure pin (10). : 4.9 N m (0.5 kgf m, 3.7 lbf ft) 9. Install boot (7) to cover (11). 3 2 1 W585-02-06-005 5. Install pushers (20) (2 used) to the bushing (2) assemblies (2 used) and install to casing (21). 6. Secure casing (21) in a vise, and tighten cover (11) with socket bolts (6) (2 used). Lip : 23.5 N m (2.4 kgf m, 17.5 lbf ft) 7. Install cam (9) onto cover (11) and secure with pin (10). W2-8-33