Komatsu — CHANGING OIL IN TRANSFER CASE

MAINTENANCE EVERY 1000 HOURS SERVICE Maintenance for every 50, 100, 250 and 500 hours service should be carried out at the same CHANGING OIL IN TRANSFER CASE Refill capacity: 6.5 liters (1.72 US gal) 1. Set a container to catch the oil under drain plug (P), then remove drain plug (P) and drain the oil. To prevent the oil from pouring out suddenly, loosen drain plug (P) and remove it gradually. 2. After draining the oil, install drain plug (P). 3. Loosen bolt (1), remove cover (2), then take out strainer (3). 4. Remove any dirt stuck to strainer (3), then wash it with clean diesel oil or flushing oil. If the strainer is damaged, replace it with a new part. 5.

Replace O-ring (4) of cover (2) with a new part, then install. 6. Refill the specified quantity of oil through oil filler (F). 7. After filling with oil, check that the oil is at the specified level. 8. Check that there is no oil leakage from the transfer case. 3-40 WA320PT-5L