CLEANING AND CHECK TURBOCHARGER MAINTENANCE If there is carbon or oil sludge around the blower impeller, it will lower the performance of the turbocharger or cause the turbocharger to fail. Contact your Komatsu Dealer to carry out inspection or repair if necessary. CHECKING ACCUMULATOR GAS PRESSURE When carrying out the EVERY 2000 HOURS SERVICE or EVERY YEAR SERVICE or when making periodic replacement of the critical safety parts, contact your Komatsu Dealer to check the accumulator gas pressure. CHECKING VIBRATION DAMPER Check for cracks or peeling on the outside surface of the rubber. If any cracks or peeling are found, contact your Komatsu Dealer to have the parts replaced.
CHECKING FUNCTION OF ACCUMULATOR PPC ACCUMULATOR If the engine stops with the work equipment raised, and it is impossible to start the engine again, it is possible as an emergency measure to actuate the valve with the oil pressure stored in the accumulator and lower the work equipment to the ground. 1. Apply the parking brake. 2. Raise the work equipment to the maximum height, then operate the lift arm control lever to HOLD position (b). 3. Stop the engine. 4. Leave the work equipment lock lever in the FREE position. 5. Check that the area around the machine is safe, then operate the lift arm control lever to FLOAT position (d) and lower the work equip- ment to a point 1m above the ground.
6. When the lift arm comes to the 1m position, return the lift arm control lever to LOWER position (c), and lower the work equipment slowly to the ground. Remark Carry out the check within 2 minutes after stopping the engine. If the machine is left with the engine stopped, the accumulator pressure will drop and it will be impossible to check the cause of the problem. If the work equipment stops while it is moving, the gas pressure WA320PT-5L 3-47