Doosan DX220A DX225LCA — Operational Checks Before Starting Engine

Operational Checks Before Starting Engine WARNING When leaving operator's seat, set the safety lever to "LOCK" (Figure 1) position, if not a serious accident could occur by accidentally moving the travel or work levers. 1. Set safety lever on "LOCK" (Figure 1). FG000211 Figure 1 2. Fasten seat belt. Check for proper operation and condition. 3. Set all operation levers in "NEUTRAL." NOTE: Be careful not to touch any switches when starting engine. 4. Rotate the starter switch to the "I" (ON) position (Figure 2). Check all indicator lights. A warning buzzer will sound for about two seconds.

After two seconds, all lights except the following will turn "OFF." O I Charging warning light Engine oil pressure warning light Engine coolant temperature gauge Fuel gauge Hydraulic oil temperature gauge Engine rpm (0 rpm) digital readout Figure 2 FG001372 NOTE: If all of the indicator lights do not come "ON" when the key is first turned, there is a problem. OP001761 3-3 Operation