Doosan DX220A DX225LCA — Hydraulic System Warm-up - Cold Weather

Hydraulic System Warm-up – Cold Weather 1. Run engine at "LOW IDLE" (no load) for five minutes (Figure 16). HAOB290L Figure 16 2. Run engine for approximately five minutes set at the middle of the speed range, without a load (Figure 17). HAOB410L Figure 17 3. Set safety lever (1, Figure 18) on "UNLOCK" position. 1 Figure 18 FG000093 4. Slowly cycle boom, arm and bucket cylinders about five times without a load to circulate the oil through the system. Do this for five minutes. FG000380 Figure 19 OP001761 Operation 3-10