Doosan DX220A DX225LCA — Change Pilot Filter (After First 250 Hours)

Change Breaker Filter Element (Optional) WARNING The hydraulic oil will be hot after normal machine operation. Allow the system to cool down before changing pilot filter. 1. Park machine on firm, level ground. Lower the front attachment to the ground and shut down engine. 2. Lift the hydraulic oil tank breather cap to release pressure. 3. Locate breaker filter assembly (Figure 46). 4. Position a container under the filter assembly. Remove the drain plug and completely drain the assembly. 5. Using a 30 mm spanner, unscrew filter housing from filter bottom. 6. Remove O-ring from filter head. 7. Replace filter. FG005867 Figure 46 8.

Apply a small amount of oil around the entire O-ring and install the filter housing on the filter head. 9. Install drain plug in bottom of filter housing. NOTE: Tightening torque: 27 kg•m (265 Nm, 195 ft lb) 10. After changing breaker filter, vent air from pump and check level of hydraulic oil tank. Change Oil in Travel Reduction Device (One on Each Side of Unit) (After First 250 Hours) NOTE: Drain and refill oil after first 250 hours of operation or rebuild, and every 1,000 hours thereafter (See page 4-44). Replace Hydraulic Oil Return Filter (After First 250 Hours) NOTE:

Replace hydraulic oil return filter after first 250 hours of operation or rebuild, then every 1,000 hours thereafter (See page 4-42). Change Pilot Filter (After First 250 Hours) NOTE: Change pilot filter after first 250 hours and every 1,000 hours thereafter (See page 4-43). OP001762 4-31 Inspection, Maintenance and Adjustment