Doosan DX220A DX225LCA — Clean Outer Filter of Air Cleaner

Clean Outer Filter of Air Cleaner NOTE: Clean outer filter every 500 hours / 3 months of service. 02/05 [MO] 11:30 NOTE: If air cleaner clogged warning light (Figure 58) on instrument panel comes "ON" the air cleaner must be serviced. E F NOTE: When working in severely dusty conditions, the service interval should be shortened. C H E/G SPEED WARNING Figure 58 FG000264 Never clean or attempt to remove the air cleaner filter if the engine is running. If using compressed air to clean the filter, make sure that proper eye protection is worn. 1. Locate the air cleaner assembly. 2 NOTE:

When it reaches every 500 hours or If indicator light (Figure 58) on instrument panel comes "ON" the air cleaner must be serviced. NOTE: Replace outer filter after cleaning 5 times or every 2,000 hours / 1 year of service. 1 FG000297 2. Remove and clean rubber evacuator valve (1, Figure 59) from bottom of air cleaner housing cover (2). Inspect seal lips for wear or damage. Replace valve if necessary. Figure 58 NOTE: Install evacuator valve with lips parallel to the cover. 3. Remove the access cover (2, Figure 60) by loosening the latches (3). 5 4. Remove outer filter (4, Figure 60) from the housing. Do not remove inner filter (5). 4 2 3 FG000702 Figure 59 1 5.

Clean the outer filter (4, Figure 60) by blowing compressed air from the inside of the filter towards the outside. Do not use more than 205 kPa (30 psi) air pressure. HAOC570L Figure 60 OP001762 Inspection, Maintenance and Adjustment 4-38