SECTION 5 MAINTENANCE Page 30 5.11. ENGINE Fig. 5.13.Crankcase Guard Oil Drain Plug Location 5.11.2.2. Changing the engine oil filter WARNING! Whenever working under the machine, turn off the electrical system master switch, remove the key and tag the controls to prevent inadvertent starting. Every 250 hours of operation change the lubrication oil filter. Fig. 5.14. Lubricating Oil Filter NOTE: Use only recommended filters available from Authorized Distributor of Construction Equipment. 1. When coolant reaches the temperature of app. 60°C, stop the engine and drain the crankcase oil. 2. Clean the filter and filter head. Unscrew the filter. 3. Clean filter head in seal contact area. 4.
Apply a little clean engine oil to the seal of new filter, fill the filter with engine oil and thread the filter on by hand per instructions specified on the filter. TD-20H DRESSTA