SECTION 5 MAINTENANCE Page 44 5.15. MOUNTED EQUIPMENT a) connect provisional hose to the quick connector on the mounted equipment valve, b) fill the hose with oil, c) connect other end of hose to the quick connector (4) on the right tilt cylinder. d) start the engine and make full tilt to the right. Keep control lever in full tilt position until full extension of the right tilt cylinder piston rod. 5. Close the quick connector. 6. Level the blade. 7. Measure the dimension „A” of tilt cylinders. 8. Repeat action 1 to 7 until you get dimension „A” on tilt cylinders equal to 170 mm ± 3 mm. 5.15.1.3.
Filling up and Venting the Tilt Cylinders of Diagonal Blade Hydraulic circuit has no connection from piston rod side of tilt cylinders to the oil tank and therefore has no capability to selfventing. After every case of disconnecting the balance hose (1), the cylinders have to be filled with oil and vented as follows: 1. Upon connection of all hydraulic lines, connect provisional filling hose (2) between one of the quick connectors located on each tilt cylinder and the quick connector on the tilt valve pressure line. 2. Connect short venting hose (3) to the quick connector on the other cylinder where filling hose is not connected. Direct the venting hose to suitable container. 3.
Start the engine with control lever pushed to the locking position and keep engine running at maximum speed until the oil leaking from venting hose (3) will be free from air bubbles. If higher pressure is required for filling and venting, it can be increased by switching from lifting circuit to the enforced lowering. Fig. 5.32. Filling and venting the tilt cylinders. 1.Balance Hose 2.Feeling Hose 3. Venting Hose 4. Quick Connectors 4. Disconnect provisional hoses (2 and 3). Raise the blade and make several full tilt cycles. 5. Check oil level in the oil tank and add if necessary. TD-20H DRESSTA