DRESSTA TD20H98/1E — 5.17.2. CHANGING THE OIL

MAINTENANCE SECTION 5 Page 49 5.16. SAFETY BELT The entire seat belt assembly should be inspected periodically for corrosion, wear, fraying or wear spots. The seat belt mounting bolts should also be periodically inspected for tightness. 5.17. FINAL DRIVES 5.17.1. CHECKING THE OIL LEVEL Position the machine on level ground so the „OIL LEVEL” mark on the final drive housing is positioned horizontally. Remove the magnetic filler and level plug, check the lubricant and, if the lubricant is low, fill to the level of the plug opening. Also, check the plug for metallic particles that may be present.

If this condition continues after periodic checks, consult Authorized Distributor of Construction Equipment. Reinstall the plug and tighten. Fig. 5.37. Checking the Lubricant Level 1. Filler and Level Plug 2. Drain Plug 5.17.2. CHANGING THE OIL While the oil is at operating or warm ambient temperature, park the machine on level ground so the „OIL LEVEL” mark on the final drive housing is positioned horizontally. Remove the drain plugs (2) and levels plugs (1) and allow the lubricant to drain into a suitable container. Remove metal particles from the magnetic plugs. Install and tighten the drain plugs. Fill app.8 liters of fuel oil up to the housing and install the plugs.

Operate the machine in low gear (with no load) for a few minutes. Remove the drain plugs and thoroughly drain the fuel oil into a suitable container. Reinstall and tighten the drain plugs. Remove the filler and level plugs. Fill the housing with fresh oil up to the bottom of the filler and level plug opening. Refer to the REFILL SPECIFICATIONS AND CAPACITIES chart for grade of lubricant specified. Reinstall and tighten the filler and level plugs. DRESSTA TD-20H