REFERENCE ONLY S11,OMLM, DN ·19·09AUG94 S11,OMLM,DO ·19·02MAR93 S11 ,OMLM,DP ·19-07JUN91 140497 PN=67 Lubrication and Maintenance/1200 Hr/2-Yr 59 Adjust engine valve clearance. (See ADJUST ENGINE VALVE CLEARANCE in Lubrication and Maintenance/400 Hours Section or have your authorized servicing dealer or engine distributor adjust the valve clearance.) IMPORTANT: Have valves adjusted after the first 400 hours of operation on new or rebuilt engines. Then, have them adjusted at 1200 Hr/2-Year interval thereafter. Check the overall fuel injection system. Also check the engine/injection pump timing, clean the injection nozzles, and adjust opening pressure.

(See your authorized diesel injection repair station, servicing dealer, or engine distributor.) On turbocharged engines, check for excessive radial or axial end play of compressor wheel (A) and turbocharger boost pressure. (See your authorized servicing dealer or engine distributor.) ADJUST ENGINE VALVE CLEARANCE CHECK FUEL INJECTION SYSTEM INSPECT TURBOCHARGER