Kaiyi HL955 — Kaiyi HL955 User Manual

6. LOADER SYSTEM AND PORT RELIEF VALVE PRESSURE TEST В SPECIFICATION Oil temperature (40~50 C) U a2 b2 a1 b1 M R D В Gauge and tool Gauge 0~35 MPa (0~350 bar , 0~5000 psi ) M : System (main) relief valve R : Bucket rollback relief D : Bucket dump relief U : Boom raise relief 1) Install fitting and pressure gauge to test port in pump delivery line. MCV 2) Install temperature reader. (see temperature reader installation procedure in this group) 3) Heat hydraulic oil to specifications. (see hydraulic oil warm up procedure in this group) 4) To check the system relief (M), run engine at high idle. Lower boom to bottomed position. Slowly activate boom down function while watching pressure gauge.

If pressure is not to specification, loosen lock nut on system relief valve (M) and adjust to specification. Do not adjust the system relief valve above 280 kg/cm 2 (3980 psi ). Damage to the pump will result from excessive pressure settings. Hyd tank Main pump 侍 757F6WE30 6-58 Relief valve Engine spee d Relief pressure System (M) LS relief valve High 280Ü5 kg/cm2 (3980Ü70 psi) Boom raise (U) Low 340Ü10 kg/cm2 (4840Ü140 psi) Bucket rollback (R) Low 340Ü10 kg/cm2 (4840Ü140 psi) Bucket dump (D) Low HL955/XTD: 300Ü10 kg/cm2 (4270Ü140 psi) HL955TM: 150Ü10 kg/cm2 (2130Ü140 psi)