hitachi — MC Fault Code List

TROUBLESHOOTING / Troubleshooting A Proportional Solenoid Valve Failure T5-5-10 Fault Code Trouble Cause Influenced Control 11412-2 Abnormal Feedback of Hydraulic Drive Fan Flow Rate Control Sole- noid Valve The feedback current to MC becomes the uncertain value Hydraulic Drive Fan Cooling Control 11412-3 Abnormal Feedback High Current of Hydraulic Drive Fan Flow Rate Con- trol Solenoid Valve The feedback current to MC exceeds the upper limit Hydraulic Drive Fan Cooling Control 11412-4 Abnormal Feedback Low Current of Hydraulic Drive Fan Flow Rate Con- trol Solenoid Valve While the command from MC is output, the feedback current to MC is 56 mA or less Hydraulic Drive Fan Cooling Control 11413-2 Abnormal Feedback of Pump Torque Control Solenoid Valve The feedback current to MC becomes the uncertain value Pump Standard Torque Control 11413-3 Abnormal Feedback High Current of Pump Torque Control Solenoid Valve The feedback current to MC exceeds the upper limit Pump Standard Torque Control 11413-4 Abnormal Feedback Low Current of Pump Torque Control Solenoid Valve While the command from MC is output, the feedback current to MC is 56 mA or less Pump Standard Torque Control 11414-2 Abnormal Feedback of Transmission Clutch First Gear Proportional Sole- noid Valve The feedback current to MC becomes the uncertain value All Transmission Control 11414-3 Abnormal Feedback High Current of Transmission Clutch First Gear Proportional Solenoid Valve The feedback current to MC exceeds the upper limit All Transmission Control