hitachi — MC Fault Code 11003

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11003 Fault Code Influenced Control 11003-3 All Control YES Faulty any sensors. Disconnect connectors of all sensors corresponding to the displayed fault code and connector monitor-1B in monitor unit. Retry. Check if fault code 11003-3 disappears. Disconnect all connectors at MC end. Check for continuity between terminals #1 and #3 of harness end connector of each sensor to MC, terminal #1 and vehicle frame. Check for continuity between terminals #27 and #32 of connector monitor-1B in monitor unit, each terminal #27, #28, #29, #30 or #31 and vehicle frame. YES Shorted circuit in harness with continuity. NO NO Faulty MC or faulty monitor unit.

· Key switch: OFF Connector (Harness end of connector viewed from the open end side) Parking Brake Pressure Sensor Pump Delivery Pressure Sensor Implement Pressure Sensor 1 2 3 Monitor Unit Connector Monitor-1B (Harness end) T4GB-05-05-002 T5-5-52 Trouble Cause Abnormal Sensor Voltage Shorted circuit in harness Faulty sensor Faulty MC 1 2 3 #27 #28 #32 #31 #30 #29 #32 #31 #30 #29