hitachi — MC Fault Code 11905

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11905 Fault Code Influenced Control 11905-2 All Transmission Control Connector (Harness end of connector viewed from the open end side) Shorted circuit in harness between between connector of forward/reverse switch and connector MC-B in MC. Disconnect connector MC-B in MC. Check for continuity between terminal #1 or #3 of connector in forward/reverse switch and vehicle frame respectively. YES NO Faulty MC. Disconnect connector of forward/reverse switch. Retry. Check if fault code disappears. NO · Key switch: ON Faulty forward/reverse switch.

YES MC Connector MC-B T183-05-04-021 Forward/Reverse Switch Connector #1 #3 T5-5-90 Trouble Cause Abnormal Forward/Reverse Switch The forward/reverse signals are turned ON for 80 ms or longer at the same time.