hitachi — Monitor Unit Fault Code 13314

TROUBLESHOOTING / Troubleshooting A MONITOR UNIT FAULT CODE 13314 Check if haness between terminal #6 of hanress end of connector 2-A in monitor unit and terminal #2 in pressure sensor is open or shorted. Faulty harness between monitor unit and pressure sensor. YES YES Faulty monitor unit. Disconnect connector of pressure sensor. Check if voltage between termnals #1 and #3 of harness end connector is 5 ± 0.5 V. Open circuit in harness between MC and pressure sensor (terminal #3). NO NO · Key switch: ON Check if voltage between termnal #1 of harness end connector in pressure sensor and vehicle frame is 5 ± 0.5 V. YES Replace pressure sensors and retry. Check if fault code disappears.

NO Open circuit in harness between MC and pressure sensor (terminal #1). NO · Key switch: ON Faulty service brake pressure sensor. Connector (Harness end of connector viewed from the open end side) YES Monitor Unit Connector 2-A Service Brake Pressure Sensor Connector #6 T183-05-04-013 T5-5-121 Fault Code Trouble Remedy 13314-3 Service Brake Pressure Sensor High Voltage Execute re-try. Check the service brake pressure sensor and harness. 13314-4 Service Brake Pressure Sensor Low Voltage Execute re-try. Check the service brake pressure sensor and harness. 1 2 3