hitachi — Engine System Troubleshooting

TROUBLESHOOTING / Troubleshooting B ENGINE SYSTEM TROUBLESHOOTING E-1 Starter does not rotate. IMPORTANT: As electric current from the key switch is not routed to safety re- lay with the forward/reverse lever or forward/reverse switch in Forward or Reverse position, the starter does not rotate. (Refer to “Electrical System / SYSTEM”.) This trouble has nothing to do with the electronic control system such as MC. Key Switch: Battery Relay: Terminal A #6 #5 #1 T178-05-04-001 T105-07-04-002 T5-6-32 Check the wiring connections first. YES Faulty neutral relay. Switch neutral relay YES with other general re- lay. Remove neutral relay. Check if starter rotates.

Check if voltage at ter- minal #3 of harness end Check if both voltages · Key switch: START NO of connector is 24 V. at key switch termi- YES · Key switch: START nals #5 and #6 are 24 V. · Key switch: ON YES Faulty key switch. Check if battery voltage Check for continuity and electrolyte density is between battery posi- normal, and fusible link tive terminal and key (100 A) is not blown. NO switch terminal #1. Faulty fuse or harness · Voltage: 24 V or more · Key switch: ON between battery and key Density: 1.26 or more NO switch. Faulty battery or faulty NO fusible link. Faulty neutral relay. Faulty battery or faulty fusible link. NO YES Faulty key switch.