hitachi — Malfunction of Buzzer in Monitor

TROUBLESHOOTING / Troubleshooting C MALFUNCTION OF BUZZER IN MONITOR Check the wiring connections first. NOTE: * Terminals L in the alternator are wa- ter-resistant type connectors so that it is not practical to measure voltage at these ter- minals. Measure voltage at terminal R in safety relay. Check for continuity between terminal R in safety relay and terminal L in the alternator first. YES Faulty engine oil pres- sure system. When engine starts, buzzer continues to sound. Check if engine oil pressure indicator lights. YES Overheated engine. Check if overheat in- dicator lights. NO Faulty monitor unit.

NO Although stop indi- cator or brake low oil pressure indica- tor lights, or high axle oil temperature is detected, buzzer does not sound. NO Normal. Check if engine speed is 900 min -1 (rpm) or faster. NO Conduct troubleshooting of lighted indicator. Check voltage at terminal L in *alternator. YES · Engine speed: 900 min -1 (rpm) or faster T5-7-4 Check if alternator in- dicator lights. YES