TROUBLESHOOTING / Troubleshooting C MALFUNCTION OF HYDRAULIC OIL TEMPERATURE INDICATOR The hydraulic oil temperature indicator is not turned on by the signal directly input from the sensors. The signal data which inputs to other controllers from the sensors once is input to the monitor unit by using the CAN communication and is proceeded in the logic circuit of monitor unit. When this trouble occurs, refer to Troubleshooting A and remedy the trouble on fault code. Although the fault code is not displayed and if the trouble occurs after re-trial, the connection be- tween monitor unit and terminal #33 or #34 of connector 2-B in monitor unit may be faulty, or the monitor unit may be faulty.
Hydraulic Oil Temperature Indicator Oil Temperature Operation Less than 95 ° C (203 ° F) OFF 105 ° C (221 ° F) or higher ON T5-7-24