hitachi — Malfunction of Monitor Display

TROUBLESHOOTING / Troubleshooting C MALFUNCTION OF MONITOR DISPLAY The data on monitor display is not displayed by the signal directly input from the sensors except one part. The signal data which inputs to other controllers from the sensors once is input to the monitor unit by using the CAN communication and is proceeded in the logic circuit of monitor unit. Therefore, check if the CAN communication is normal first and check if the sensors correspond- ing to the trouble are normal. T5-7-50 Description Cause of Trouble Data on liquid crystal display Neutral indicator If the data of monitoring function can be displayed on Dr.

ZX, CAN communication between monitor unit and other controllers is faulty. If the data cannot be displayed on Dr. ZX, the sensor system detecting the related signal is faulty. (As for the machine, some trouble must occur. Refer to Troubleshooting A and conduct the remedy.) Forward/reverse indicator Driving mode indicator Hold indicator Speedometer Automatic mode indicator Clutch cut-off indicator Ride control indicator Refer to T5-7-51. Data on data display Model Displayed on service mode when starting only If the data of monitoring function can be displayed on Dr. ZX, CAN communication between monitor unit and other controllers is faulty. If the data cannot be displayed on Dr.

ZX, the sensor system detecting the related signal is faulty. (As for the machine, some trouble must occur.

Refer to Troubleshooting A and conduct the remedy.) Clock (24 hours) Fuel consumption amount Average fuel consumption amount Odometer Displayed on service mode when starting only Engine speed Displayed on service mode when starting only Hydraulic oil temperature Displayed on service mode when starting only Fault code Displayed on service mode when starting only Transmission oil temperature Displayed on service mode when starting only Other data Displayed on normal mode when starting only As for these troubles, the liquid crystal display in monitor unit may be faulty or the logic circuit may be faulty.

• Remainder time that hydraulic oil can be used • Remainder time that hydraulic oil filter can be used • Remainder time that transmission oil can be used • Remainder time that transmission oil filter can be used Remainder time that engine oil can be used Remainder time that engine oil filter can be used Remainder time that fuel filter can be used Hour meter The alternator is faulty, the harness between terminal L in the alternator and terminal #2 of connector 2-A in monitor unit is faulty, or the clock circuit in monitor unit may is faulty. Coolant tempera- ture Displayed on service mode when starting only Refer to T5-7-52.