hitachi — Fuse Inspection

TROUBLESHOOTING / Electrical System Inspection FUSE INSPECTION Cracks in a fuse are so fine that it is very difficult or impossible to find by visual inspection. Use a tester in order to correctly inspect fuse continuity. Inspect the fuse by following the instructions described below. 1. Turn Key Switch ON When the key switch is turned ON, current from terminal M of key switch activates the battery re- lay so that electric power is supplied to all circuits. (Refer to the circuit diagram.) 2. Remove the fuse box cover. Set the tester volt- age in order to meet the circuit specification to be measured. (Measurement Range: 0 to 30 V) 3. Ground the negative probe of the tester to the machine.

Touch the terminals located away from the center of the fuse box with the positive probe of tester one at a time. When normal continuity of a fuse is intact, the tester will indicate 20 to 25 V (battery voltage). NOTE: All terminals located along the lengthwise centerline of the fuse box are connected to the power source, while terminals located away from the center of the fuse box are connected to loads (accessories). There- fore, test all fuses in the same method ex- cept for the glow plug relay circuit fuse. Check the glow plug relay circuit fuse with the key switch turned ON according to the procedure in step 3. T5-8-6