TROUBLESHOOTING / Electrical System Inspection VOLTAGE AND CURRENT MEASURE- MENT Turn key switch ON so that the specified voltage (cur- rent) is supplied to the location to be measured. Judge if the circuit is normal by evaluating whether the measured voltage (current) matches the specification. 24-Volt Circuit Start checking the circuit in order up to the loca- tion to be measured from either power source or actuator side. Thereby, the faulty location in the circuit will be found. Black Probe (Negative) of Tester: To ground to the vehicle frame Red Probe (Positive) of Tester: To touch the location to be measured cable from the battery.
T5-8-14 Engine Key Switch Location to be Measured Specification Power Source Circuit Stopped Stopped Stopped Stopped Stopped Stopped OFF OFF OFF OFF OFF OFF Between (2) and (1): One Battery Between (3) and (2): One Battery Between (3) and (1): Two Batteries Between (4) and Ground: Battery Power Between (5) and Ground: Fusible Link Between (1) and Ground: Backup Current* 10 to 12.5 V 10 to 12.5 V 20 to 25 V 20 to 25 V 20 to 25 V 6 mA Preheat Circuit Started Started START START Between (6) and Ground: Key Switch Between (7) and Ground: Glow Plug 20 to 25 V 20 to 25 V Starting Circuit Started Started Started Started Started Started START START START START START START Between (8) and Ground:
Key Switch Between (9) and Ground: Battery Relay (Coil) Between (10) and Ground: Battery Relay (Switch) Between (11) and Ground: Starter (B) Between (12) and Ground: Starter (S) Between (13) and Ground: Starter Relay 2 (S) 20 to 25 V 20 to 25 V 20 to 25 V 20 to 25 V 20 to 25 V 20 to 25 V Charging Circuit Fast Speed Fast Speed Fast Speed Fast Speed ON ON ON ON Between (14) and Ground: Alternator (B) / Generating Voltage Between (10) and Ground: Battery Relay / Generating Voltage Between (15) and Ground: Generating Voltage Between (16) and Ground:
Monitor 26 to 30 V 26 to 30 V 13 to 30 V 13 to 30 V Surge Voltage Prevention Circuit Idle Speed Idle Speed Idle Speed Idle Speed ON→OFF ON→OFF ON→OFF ON→OFF Between (14) and Ground: Alternator (B) Between (15) and Ground: Starter Relay 1 (R) Between (17) and Ground: Load Damp Relay Between (10) and Ground: Battery Relay 26 to 30 V 13 to 30 V 26 to 30 V 26 to 30 V Accessory Circuit Stopped ON Between (18) and Ground: Radio 20 to 25 V NOTE: *Measure after disconnecting the negative