Section 7 – Adjustment, Repair, and Replacement Page 7-197 CFP83 Series Lubricating Oil Pump Removal/Installation (Cont) Inspect the lubricating oil pump housing and gerotor drive for damage and excessive wear. CAUTION Make sure the gerotor planetary is installed in the original position. Failure to do so can damage the oil pump. Install the gerotor planetary. Measure Measure the tip clearance. MAX Limit 0.1778 mm [0.007 in] Drawing No. 9777, Section 7, Rev. 02-07