CNH T8000 — AUTOMATIC TEMPERATURE CONTROL (ATC) OPERATION

Section 50 - Climate Control - Chapter 1 50-1-31 CONNECTOR J8 TEST POINTS Test Instructions and Actions 10 Test cab temperature sensor: Pin 21 to Battery GND Condition(s): Keyswitch ON and ATC Switch to “AUTO” Expected Result: 0.5V at 70°F (21°C) at the sensor. Voltage decreases as temperature increases. Actions: If no voltage, replace the controller. If voltage out of range for temperature, test sensor. See sensor test. 12 Test temperature control pot output: Pin 29 to Battery GND Condition(s): Keyswitch ON and ATC switch to “AUTO” Expected Result: 0.0 to 3.0V while turning temperature control from full CCW to full CW Actions: If no voltage, replace the controller.

13 Test blower speed control pot output: Pin 28 to Battery GND Condition(s): Keyswitch and A/C switch ON Expected Result: 0.0 to 3.0V while turning blower speed pot from full CCW to full CW Actions: If no voltage, replace the controller. 14 Test mode door control pot output: Pin 30 to Battery GND Condition(s): Keyswitch and A/C switch ON Expected Result: 0.0 to 3.0V while turning mode door control from full CCW to full CW Actions: If no voltage, replace the controller. 15 Test Defog/Defrost switch control function - : Pin 25 to Battery GND Condition(s): Keyswitch ON and ATC Switch OFF Expected Result: 5V Actions: If no voltage, replace the controller.

16 Test ATC switch control function - Automatic mode: Pin 26 to Battery GND Condition(s): Keyswitch ON and ATC Switch OFF Expected Result: 5V Actions: If no voltage, replace the controller.