CNH T8000 — BLOWER AND BLOWER SPEED DRIVER

Section 50 - Climate Control - Chapter 1 Cab Temperature Sensor and Circuit Test 50-1-53 Steps and Test Point Corrective Actions 1. Keyswitch OFF. Disconnect the cab temperature sensor from harness. Measure the resistance across the sensor leads. Measure the ambient temperature at the sensor. Compare the readings to the Temperature versus Resistance table on page 55. Is the resistance reading within the minus or plus 2.5% range in the table? YES - Go to next Step. NO - Replace the sensor. 2. Keyswitch ON and ATC switch to “Auto”. Measure voltage at female connector on sensor. Is voltage present? NOTE: Voltage reading will be very low:

0.5V at 70°F (21°C); and voltage decreases as temperature increases. YES - Go to next Step 4. NO - Go to next Step. 3. Measure voltage at CJ8-21 at the controller. Is voltage present? YES - Locate and repair open condition between CJ8- 21 at the controller and the sensor. NO - Test the controller. See ATC Controller Test in this Section. Perform tests 1, 2, and 10. 4. Measure resistance from ring terminal on the sensor to HVAC ground. Less than 1 ohm? YES - Wrong reading taken. Retest. NO - Locate and repair open condition between sensor and HVAC ground.