Section 50 - Climate Control - Chapter 1 Controller Power, Ground, And ATC Switch NOTE: See Electrical Schematic sections 60 and 61. Background HVAC ground is a grounding bolt at the back of the HVAC box. Ground is additionally provided from the common wires through CJ6R1 on wire 309- or to ring terminal C2. Since so many controlled directed components interact, intermittent HVAC ground can make reliable troubleshooting very difficult. The “intermittent” nature of the problem is further complicated since the fault can appear to move from component to component.
Early testing for a stable and consistent ground at the HVAC ground bolt and CJ6R1 to ring terminal C2can greatly simplify troubleshooting. Power and Ground Circuit ATC Controller Whenever accessory power is present, 12V is fed the controller from fuse 47 (30 amp) through CJR6R1 to CJ8-17. The controller is grounded from CJ8-18 to HVAC ground. ATC Switch The controller feeds 5V CJ8-26 through CJ6R1-L to the switch at pin 4; grounding CJ8-26 with the switch provides the automatic mode request to the controller. The controller feeds 5V from CJ8-25 through CJ6R1-M to the switch at pin 6; grounding CJ8-26 with the switch provides the Defog/Defrost mode request to the controller.
The switch is grounded from pin S to chassis at CJ6R1-S. Possible Failure Modes 1. Fuse 47 or open condition in power or ground to controller. 2. ATC switch failure. 3. Open condition in power or ground to switch. Controller Power Supply and Ground Test 50-1-56 Steps and Test Point Corrective Actions 1. Keyswitch ON and ATC switch to “A.” Measure the voltage between CJ8-17 at the controller and chassis ground. Is 12V present? YES - Go to Step 3. NO - Go to next Step. 2. Check fuse no. 47 (30 amp). Is 12V present? YES - Locate and repair open condition between fuse 36 and pin CJ8-17 at the controller. NO - Locate and repair open condition from fuse 36 to switched B+. Go to next Step. 3.
Measure resistance from pin 18 at the controller to HVAC ground. Less than 1 ohm? YES - See ATC Controller Tests. in this Section. Test the pins directly related to the faulty component at the controller. NO - Locate and repair open condition from pin 18 to HVAC ground.