Section 50 - Climate Control - Chapter 2 Complete Circuit Flushing Procedure with Power Flush 17550 STEP 65 All refrigerant must be recovered from the system before flushing. STEP 66 The 17550 power flush unit uses shop air to atomize the flushing solvent and a pulsing action to scrub residue and contaminants out of components. Fill the flushing reservoir 3/4 full with approved New Holland flushing solvent. Do not overfill the reservoir or you will restrict the pulsing action of the unit. RD00H209 STEP 67 Remove the receiver-drier and join the hoses together with an adapter hose. Discard the receiver- drier.
RI00G029 STEP 68 Remove the thermal expansion valve and use adapters to connect the hose lines to the evaporator. RI00G018 50-2-41