CNH T8000 — A/C SYSTEM FLUSHING PROCEDURE

Section 50 - Climate Control - Chapter 2 Final System Oil Check After the system has been drawn to a deep vacuum and recharged, 3. Recover refrigerant from the system. Use the dipstick method to check the PAG oil level in the compressor. If needed, adjust the oil level. See Dipstick Method , page 80. For all Tractor Models, the oil should cover five lines on the dipstick. 1. Operate the A/C system for 15 minutes to thoroughly circulate the PAG oil throughout the system. 2. Install the gauge set and test the A/C system for proper operation referring to the pressure/ temperature table on Page 33. 4. Evacuate and recharge the system. IMPORTANT:

If oil level was measured and adjusted properly according to the guidelines, Steps 3 and 4 are unnecessary. Flushing Solvent Disposal Never reuse contaminated flushing solvent. Good stewardship of our natural resources is everyone’s business. New Holland flushing solvent is a hazardous material. Never dispose of this solvent by pouring it down the drain or treating it as water soluble waste. Observe all local, state and federal regulations when disposing the solvent. In the United States, SAFETY-KLEEN will recycle used flushing solvent. For more information on SAFETY-KLEEN’s recycling program, call 800-323- 5040. 50-2-50