CNH T8000 — TROUBLESHOOTING

Section 25 - Four-Wheel Drive Front Axle - Chapter 1 TROUBLESHOOTING Problem – FWD clutch will not disengage 1. Check for PTO fault codes. (FWD fault codes are monitored by PTO controller.) A. If fault codes are found, follow procedures outlined in PTO system fault code troubleshooting in this section. 2. Place the FWD switch in the OFF position. Check the tractor monitor for the FWD icon in the instrumentation display. A. If the FWD icon is not displayed, this is an indication the electrical control circuit is functioning correctly. Go to Step 4. B. If the FWD icon is displayed, this in an indication the electrical control circuit is not functioning correctly.

Check fault codes, controller, and data bus function. 3. Place the FWD switch in the OFF position. Check for 12 VDC at FWD valve coil. A. If 12 VDC is available to the coil, the electrical circuit is functioning properly. B. If 12 VDC is not found, troubleshoot the FWD electrical circuit. 1. Check wires 540B R and 175D (BK) (ground). 2. Check all connections for excessive resistance. Place the FWD switch in the manual ON position. Check for 12 VDC at FWD valve coil. C. If 12 VDC is not available to the coil, the electrical circuit is functioning properly. D. If 12 VDC is found, troubleshoot the FWD electrical circuit. 3. Check wires 540B (R) and175D (BK) (ground). 4.

Check all connections for excessive resistance. 4. Start and run the engine. A. Press the INCR or DECR key on the programmable instrumentation until the TRANS OIL TEMP screen is reached. NOTE: Screen order is set by the operator. The TRANS OIL TEMP and TRANS SYS PRESSURE screens could or could not be together depending on setup. B. Operate the engine at 1500 RPM until the transmission temperature displayed on the instrumentation reads at least 49 ° C (120 ° F). C. Press the INCR key as required to display the TRANS SYS PRESSURE screen. 5. While viewing the display, deactivate the FWD. The display pressure should dip, then recover to normal regulated pressure.

If the pressure dips but does not recover, there is a leak in the FWD circuit. Repeat this check several times. A. Inspect the FWD valve cartridge for leaking seals. B. Inspect the FWD clutch for leaking seals. 6. Check and repair the FWD clutch as needed. 25-1-10