Section 35 - Hydraulic Systems, 3PT - Chapter 1 Valve spools are controlled by levers, pedals, pilot oil, electric solenoids, etc., which are called actuating controls. These actuating controls are shown by symbols placed on the ends of the envelopes. SOLENOID CONTROL WITH INTERNAL PILOT PRESSURE SPRING SPRING THREE POSITION, SPRING CENTERED To show that a valve is spring centered, a spring symbol is placed at each end of the envelope. The above schematic shows that an electrical solenoid and pilot pressure assist are required to overcome spring force to move the valve spool.
713L8C Flow Control Symbols Restrictors NON ADJUSTABLE RESTRICTOR ADJUSTABLE RESTRICTOR 716L8B 716L8A The basic flow control symbol is a representation of a restrictor. If the restrictor is adjustable, a slanted arrow is drawn across the symbol. The restrictor could be a special fitting with a small hole in it or a small drilled passageway within a valve. If it is an adjustable restriction, it could be thought of as a water faucet that can be controlled by turning the handle to regulate the flow. Restrictors can be applied to meter out, meter in and bleed off circuits.
ADJUSTABLE RESTRICTOR PRESSURE COMPENSATED ADJUSTABLE RESTRICTOR PRESSURE AND TEMPERATURE COMPENSATED 716L8D 716L8C There are adjustable restrictors that are pressure compensated. That means that the size of the opening in the restrictor will change with increases and decreases in pressure. A perpendicular arrow indicates pressure compensation. If the restrictor has both pressure and temperature compensation, the symbol for a thermometer will also be shown. 35-1-10