Section 35 - Hydraulic Systems, 3PT - Chapter 2 Regulated Pressure Circuits The regulated circuit is supplied by the front dual gear pump. The pump flow passes through the regulated circuit filter housing and onto the priority regulator valve. The pressure regulator portion of the valve maintains the regulated pressure at 22.4 to 24.5 bar (325 to 355 PSI). The following components are supplied by the regulated circuit:
speed transmission powershift valve, odd/even transmission powershift valve (includes creep and park brake), range transmission powershift valve (includes FWD), PTO/differential lock valve, master clutch inching valve, brake valve, hitch valve pilot pressure, remote valve pilot pressure and FWD clutch supply. 1 2 5 8 3 4 7 RI06A086 1. RANGE REGULATED SUPPLY TUBE 6. MASTER CLUTCH DIAGNOSTIC COUPLER 2. SPEED TRANSMISSION CONTROL VALVE REGULATED SUPPLY-UPPER TUBE 7. TRANSMISSION CONTROL VALVE REGULATED SUPPLY 3. PRIORITY REGULATOR VALVE TO PTO VALVE 8. PRIORITY REGULATOR VALVE EXCESS TO OIL COOLERS 4. PRIORITY REGULATOR VALVE 9. REGULATED CIRCUIT ACCUMULATOR 5. MASTER CLUTCH DIAGNOSTIC TUBE 10.
SPEED TRANSMISSION CONTROL VALVE REGULATED SUPPLY-LOWER TUBE NOTE: Brake, hitch and remote valves regulated supply tubes not shown. See brake, hitch and remote circuits in this section. 35-2-12