Section 35 - Hydraulic Systems, 3PT - Chapter 2 STEP 2- Flow Measurement NOTE: It is not necessary to heat the hydraulic system for this test, but the system should be near room temperature 70 ° F (21 ° C). - Place the transmission control lever into “P” park position. - Start and run the engine at 2000 RPM. - Adjust the flowmeter load setting to approximately 300 PSI (20.7 bar). - Record the flow reading: Front Regulated pump flow reading at 2000 RPM_____________ at 300 PSI (20.7 bar). Front Regulated Pump flow specification: 27.0 GPM (102.2 L/min) minimum at 2000 RPM. A. If the pump flow is 24.0 GPM (90.8 L/min) or greater, the regulated pump is functioning correctly. B.
If the pump flow is 21.6 to 24.0 GPM (81.8 to 90.8 L/min), the pump output is adequate, but the pump efficiency is low. C. If the pump flow is below 21.6 GPM (81.8 L/min), replace the front regulated pump. 35-2-26