Section 35 - Hydraulic Systems, 3PT - Chapter 2 PFC PISTON PUMP FLOW TEST Perform this test when all remote circuits and the hitch system are not operating at full flow. This would be noticeable by slower operation of remote circuit systems along with a slower hitch raise time. - Set all the remote valve variable flow controls to the maximum flow position. - Set the remote valve timer control to the maximum time position. - Cover the oil coolers on to help heat the oil. - Start and run the engine at 1000 RPM. NOTE: Use 3/4 inch hose with a minimum working pressure of 3000 PSI (206 bar) for this flow test. - Install the CAS-10280 Flowmeter into the No. 1 remote section.
Place the remote valve control lever into the detent retract position. - Adjust the load valve on the flowmeter to 1500 PSI (103 bar) and heat the transmission oil to a minimum of 120°F (49°C). 1A 1B 1B 1A RD98E117 Increase engine speed to 2000 RPM. Individually flow rate each remote valve section. Adjust the load valve on the flowmeter to 1000 PSI (69 bar). Full Flow Specification for Standard Flow Pump: 34.3 GPM (130 L/min) Full Flow Specification for Optional High Flow Pump: 34.3 GPM (130 L/min) Full Flow Specification for Optional MegaFlow Pump: 34.3 GPM (130 L/min) If only one remote section is delivering the correct flow and the rest record low flow.
Inspect the signal check for the remote section that is delivering the correct flow. This signal check is probably leaking. If the pump does not meet specification for standard flow pump, perform the Standard Pump Compensator and Swash Plate Inspection. 35-2-45 REMOTE SECTION FULL FLOW @ 2000 RPM NO. 1 REMOTE SECTION NO. 2 REMOTE SECTION NO. 3 REMOTE SECTION NO. 4 REMOTE SECTION NO. 5 REMOTE SECTION