Section 35 - Hydraulic Systems, 3PT - Chapter 5 REMOTE VALVE OPERATION General MAIN VALVE SPOOL - The main valve spool is spring centered in neutral and is positioned by the proportional current control solenoids. The spool position determines the flow rate and the flow path of the supply flow. When lowering, oil is fed to the left hand side of the plunger. The plunger will be forced up against the load check pilot poppet to relief trapped pressure. The plunger then contacts the main poppet moving it to the left allowing flow back to tank.
PRESSURE-COMPENSATED FLOW CONTROL SPOOL - Each valve section contains a pressure compensated flow control spool which functions to maintain a constant pressure drop across the main valve spool. This constant pressure drop results in a constant flow rate across the main valve spool. SIGNAL CHECK TO COMPENSATOR - The signal check isolates each remote valve’s operating pressure from the other valves in the system. When more then one remote valve section is in operation, the valve operating at the higher pressure will signal the compensator on the PFC pump.
LOAD CHECK AND PLUNGER - The load check is installed in the “B” extend port to prevent the settling of a load (in neutral) because of control spool leakage. It also serves as a check valve to prevent a drop in a partially raised cylinder when the remote valve is operated. SIGNAL CHECK PILOT RELIEF- Each remote section is equipped with a second relief signal check that limits each remote sections maximum pressure. 35-5-14