Section 35 - Hydraulic Systems, 3PT - Chapter 5 Float pressure standby pressure is directed to the backside of the load check plunger. The plunger moves to the right, unseating the load check main poppet. When the remote hydraulic control lever is moved to the float position, the main valve spool is moved to the far right position by the proportional solenoid pressure supply. When the extend and retract work ports are connected to the return to filter inlet it allows the implement to float and follow the contour of the ground. The valve will now float a double acting or single acting cylinder. The main valve spool lands block flow to the extend and retract ports.
At the same time the main valve spool opens the work ports to the return to filter inlet. To unseat the load check on the raise port low 2 1 3 6 7 4 5 15 14 8 13 9 12 10 11 9 13 RI02F018 1. EXTEND PORT 9. REGULATED PRESSURE SUPPLY 2. RETRACT PORT 10. BACK TO TANK 3. LOAD CHECK PLUNGER 11. SIGNAL LINE TO COMPENSATOR 4. MAIN VALVE SPOOL 12. TO REMOTE SIGNAL RELIEF VALVE 5. PRESSURE COMPENSATED FLOW CONTROL SPOOL 13. PILOT DRAIN 6. PROPORTIONAL SOLENOID (EXTEND) 14. SIGNAL CHECK TO PUMP COMPENSATOR 7. PROPORTIONAL SOLENOID (RETRACT) 15. SIGNAL CHECK PILOT RELIEF 8. PFC PUMP SUPPLY 35-5-21