Section 35 - Hydraulic Systems, 3PT - Chapter 5 REMOTE VALVE COUPLER TEST Find out what type of male coupler tip is being used. Remote valve couplers seal leaks will cause the following problem. Male coupler tip spit out when remote valve lever is engaged. Implement settles when attached to tractor. Low remote flow through the coupler. Check the male tip and make sure it is compatible with the tractor (the male tip must have ball on the end or it will damage the female cartridge tip). Check to make sure the implement supply and return hoses are properly supported to prevent unnecessary loading of the female coupler cartridge. Inspection Clean the coupler.
Remove all dirt from inside the detent mechanism. This is a mechanical connection, coupler balls must be free to move. Talk to the owner/operator about the problem. RH02J046 REMOTE COUPLER ASSEMBLY 35-5-32