Section 50 - Climate Control - Chapter 1 AUTOMATIC TEMPERATURE CONTROL (ATC) OPERATION The ATC controller is a closed loop control device which takes the data from a variety of inputs and executes output instructions to the devices it controls. The controlling parameter for the system is cab inside temperature . The operator selects a desired cab temperature with the temperature control. The controller uses the compressor, heater control valve and blower speed to drive to and maintain the desired setpoint. It also uses the mode door to effectively distribute the cooled or warmed air in the cab. The controller receives input from the following controls and sensors:
To accomplish its heating and cooling functions, the controller uses the following output devices: 50-1-12 ATC Switch on the desired operational mode for the system:
Off, Automatic or Defog/Defrost, Cab Temperature Sensor located at the recirculated air return, on current cab temperature, Setpoint Temperature selected by the operator with temperature control, on desired cab temperature, Evaporator Temperature Sensor inserted in the evaporator/heater assembly, on current cooling or heating temperatures, Low Pressure Switch on the status of abnormal system pressures on the low side, High Pressure Switch on the status of abnormal system pressures on the high side, Blower Speed Control when the operator chooses to override the blower speed selected by the controller, and ° F/°C Display Selector which changes temperature display from Fahrenheit to Celsius.
Compressor Clutch via Clutch Relay to engage or disengage the compressor to achieve the desired cab cooling setpoint, Heater Control Valve by varying the valve opening, to achieve the desired cab heating setpoint, Blower Speed via Blower Speed Driver to deliver the conditioned air from the evaporator/heater assembly at a speed proportional to the gap between the current cab temperature and the desired setpoint, and Instrument Cluster Display (in Instrument Cluster) to display the desired cab temperature setpoint, operational modes, system status and fault codes.